Siemens SIMATIC S7 300 6AG1332-5HF00-2AB0 HMI Case
Siemens SIMATIC S7 300 6AG1332-5HF00-2AB0 HMI Case
Siemens SIMATIC S7 300 6AG1332-5HF00-2AB0 HMI Case
Siemens SIMATIC S7 300 6AG1332-5HF00-2AB0 HMI Case
Siemens SIMATIC S7 300 6AG1332-5HF00-2AB0 HMI Case
Siemens SIMATIC S7 300 6AG1332-5HF00-2AB0 HMI Case
Model
6AG1332-5HF00-2AB0

Item specifics

Brand
Siemens
Warranty
365 Days
Product Line
Siemens SIMATIC S7-300 Plastic Housing
Supply
Siemens SIMATIC S7 300 SM 332 analog output module
Siemens S7-300
6AG1332-5HF00-2AB0
Model
6AG1 332-5HF00-2AB0
Number
6AG13325HF002AB0

Review

Description

6AG1332-5HF00-2AB0 Siemens SIMATIC S7-300 Module Housing Repair Replacement


6AG1332-5HF00-2AB0 Siemens SIMATIC S7-300 analog output module SM 332 Plastic Shell Repair Replacement

S7-300 6AG13325HF002AB0 SM 332 analog output modules HMI Case systems are intended for stationary use in locations protected against the weather. The operating conditions surpass the requirements of DIN IEC 60721-3-3.
 Class 3M3 (mechanical requirements)
 Class 3K3 (climatic requirements)


Analog output module SM 332; AO 8 x 12 bit; 6AG1332-5HF00-2AB0 Plastic Shell Properties
• 8 outputs in one group
• The output can be selected by individual channel
– Voltage output
– Current output
• Resolution 12 bits
• Programmable diagnostics and diagnostic interrupt
• Programmable diagnostic interrupt
• Electrically isolated from the backplane bus interface and load voltage
• Supports parameter reassignment in RUN


VICPAS supply 6AG1332-5HF00-2AB0 Siemens S7 300 Simatic Module Plastic Case Cover Replacement Part. All of them with VICPAS 365 days warranty and support Urgent Worldwide Shipping.





Specifications:

The table below describes the parameters of the 6AG1332-5HF00-2AB0 Siemens SIMATIC SM 332 analog output modules Case Parts.

Part Number : 6AG1332-5HF00-2AB0
Atmospheric pressure: 1080 to 660 hPa
Temperature: –40 °C to +70°C
Warranty: 365 days Warranty
Product Line: Siemens Simatic S7-300
Dimensions W x H x D (mm): 40 x 120.4 x 110.8
Safety isolation: SELV circuit
Power consumption: 57 W
Power loss: Typ. 9 W
Efficiency: 84 %


Related Siemens Simatic S7-300 Part No. :

Siemens Simatic S7-300 Description Inventory status
6AG1331-1KF02-7AB0 Siemens SIPLUS S7-300 Plastic Case SM 331 Replacement Available Now
6AG1331-7KB02-2AB0 SIMATIC S7 300 SM 331 Plastic Shell Repair Part In Stock
6AG1331-7KF02-2AB0 Siemens S7-300 SM 331 Housing Enclosure Repair Available Now
6AG1331-7NF00-2AB0 Siemens S7-300 SM 331 Plastic Shell Replacement In Stock
6AG1331-7NF10-2AB0 Siemens S7-300 SM 331 Plastic Case Replacement In Stock
6AG1331-7PF01-4AB0 SIMATIC S7 300 SM331 HMI Enclosure Replacement In Stock
6AG1331-7PF11-4AB0 SIMATIC S7 300 Plastic Case SM 331 Replacement Available Now
6AG1332-5HB01-2AB0 Siemens S7-300 SM 332 Housing Repair Replacement Available Now
6AG1332-5HD01-7AB0 Siemens S7-300 Plastic Shell SM 332 Repair In Stock
6AG1332-5HF00-2AB0 SIMATIC S7 300 HMI Case SM 332 Replacement Available Now
6AG1332-7ND02-4AB0 Siemens S7-300 SM 332 Housing Replacement In Stock
SIPLUS S7 300 PLC Description Inventory status

Siemens SIMATIC S7-300 HMI Manuals PDF Download:

  • 6AG13325HB012AB0 Datasheet
  • 6AG13325HD017AB0 Datasheet
  • 6AG13325HF002AB0 Datasheet
  • SIEMENS SIMATIC S7-300 Getting Started for First Time Users
  • SIEMENS SIMATIC S7-300 Module Data Equipment Manual 2022
  • SIEMENS SIMATIC S7-300 Module Data Manual 2013
  • SIEMENS SIMATIC S7-300 Module Data Manual 2017
  • SIEMENS SIMATIC S7-300 Programmable Controller Hardware and Installation Manual
  • SIEMENS SIMATIC S7-300 Programmable Controller Module Specifications Reference Manual
  • SIEMENS SIMATIC S7-300

  • FAQ:

    Question: Putting a New 6AG1332-5HF00-2AB0 Plastic Case Cover Body Module into Service

    Answer: Proceed as follows to put the new module into service:
    1. Open the front panel.
    2. Reinstall the front connector.
    3. Close the front panel.
    4. Switch the load voltage back on.
    5. Set the CPU to RUN mode again.
    Putting a New 6AG1332-5HF00-2AB0 Plastic Case Cover Body Module into Service


    Question: When should I use expansion devices?

    Answer: You can use EDs if the number of CU slots is insufficient for your application.
    When using EDs, you might require further power supply modules in addition to the extra module racks and interface modules (IM). When using interface modules, you must ensure compatibility of the partner stations.


    Common misspellings: 

    6AG1332-5HF00-2B0
    AG1332-5HF00-2AB0
    6AG1332-5FH00-2AB0
    6AG1332-5HF00-2A80
    6AAG1332-5HF00-2AB0