Siemens SIMATIC S7 300 6ES7321-1EL00-0AA0 Plastic Cover
Siemens SIMATIC S7 300 6ES7321-1EL00-0AA0 Plastic Cover
Siemens SIMATIC S7 300 6ES7321-1EL00-0AA0 Plastic Cover
Siemens SIMATIC S7 300 6ES7321-1EL00-0AA0 Plastic Cover
Siemens SIMATIC S7 300 6ES7321-1EL00-0AA0 Plastic Cover
Siemens SIMATIC S7 300 6ES7321-1EL00-0AA0 Plastic Cover
Model
6ES7321-1EL00-0AA0

Item specifics

Brand
Siemens
Warranty
365 Days
Product Line
Siemens SIMATIC S7-300 Plastic Shell
Supply
Siemens SIMATIC S7 300 SM 321 digital input module
Siemens S7-300
6ES7321-1EL00-0AA0
Model
6ES7 321-1EL00-0AA0
Number
6ES73211EL000AA0

Review

Description

Siemens SIMATIC S7-300 Module 6ES7321-1EL00-0AA0 Plastic Shell Repair Replacement


Siemens SIMATIC S7-300 SM 321 digital input modules 6ES7321-1EL00-0AA0 Enclosure Repair Replacement

The S7-300 6ES7 321-1BH50-0AA0 Module HMI Case, for example, must not be used without taking additional measures:
 in locations exposed to a high degree of ionizing radiation
 in hostile environments caused, for instance, by
– dust accumulation
– corrosive vapors or gases
– strong electric or magnetic fields
 in installations requiring special monitoring, for example
– elevators
– electrical installations in particularly hazardous areas
An additional measure might be, for instance, installation of the S7-300 6ES7321-1EL00-0AA0 Plastic Case in a cabinet or in a housing.


Digital output module SM 321; DI 32 x AC 120 V; (6ES7321-1EL00-0AA0 Enclosure) Properties
Properties of SM 321; DI 32 x AC 120 V:
● 32 inputs, electrically isolated in groups of 8
● Rated input voltage 120 VAC
● Suitable for switches and 2-/3-wire AC proximity switches




Specifications:

The table below describes the parameters of the Siemens SIMATIC SM 321 digital input modules 6ES7321-1EL00-0AA0 Plastic Case Parts.

Atmospheric pressure: 1080 to 660 hPa
Part Number : 6ES7321-1EL00-0AA0
Product Line: Siemens Simatic S7-300
Temperature: –40 °C to +70°C
Warranty: 365 days Warranty
Dimensions W x H x D (mm): 40 x 120.4 x 110.8
Efficiency: 84 %
Power consumption: 57 W
Power loss: Typ. 9 W
Safety isolation: SELV circuit


Related Siemens Simatic S7-300 Part No. :

Siemens Simatic S7-300 Description Inventory status
6ES7195-7KF00-0XA0 Siemens S7-300 safety protector HMI Case Replacement In Stock
6ES7321-1BH02-0AA0 Siemens SIPLUS S7-300 Plastic Case SM 321 Replacement Available Now
6ES7321-1BH10-0AA0 SIMATIC S7 300 SM 321 Plastic Shell Repair Part In Stock
6ES7321-1BH50-0AA0 Siemens S7-300 SM 321 Housing Enclosure Repair Available Now
6ES7321-1BL00-0AA0 Siemens S7-300 SM 321 Plastic Shell Replacement In Stock
6ES7321-1CH00-0AA0 Siemens S7-300 SM 321 Plastic Case Replacement In Stock
6ES7321-1CH20-0AA0 SIMATIC S7 300 SM321 HMI Enclosure Replacement In Stock
6ES7321-1EL00-0AA0 SIMATIC S7 300 Plastic Case SM 321 Replacement Available Now
6ES7321-1FF01-0AA0 Siemens S7-300 SM 321 Housing Repair Replacement Available Now
6ES7321-1FF10-0AA0 Siemens S7-300 Plastic Shell SM 321 Repair In Stock
6ES7321-1FH00-0AA0 SIMATIC S7 300 HMI Case SM 321 Replacement Available Now
6ES7321-7BH01-0AB0 Siemens S7-300 SM 321 Housing Replacement In Stock
6ES7321-7RD00-0AB0 SIMATIC S7-300 SM 321 HMI Enclosure Repair Available Now
SIPLUS S7 300 PLC Description Inventory status

Siemens SIMATIC S7-300 HMI Manuals PDF Download:

  • 6AG13211BH022AA0 Datasheet
  • 6AG13211CH202AA0 Datasheet
  • SIEMENS SIMATIC S7-300 Getting Started for First Time Users
  • SIEMENS SIMATIC S7-300 Module Data Equipment Manual 2022
  • SIEMENS SIMATIC S7-300 Module Data Manual 2013
  • SIEMENS SIMATIC S7-300 Module Data Manual 2017
  • SIEMENS SIMATIC S7-300 Programmable Controller Hardware and Installation Manual
  • SIEMENS SIMATIC S7-300 Programmable Controller Module Specifications Reference Manual
  • SIEMENS SIMATIC S7-300

  • FAQ:

    Question: What is the 6ES7321-1EL00-0AA0 Siemens Simatic S7-300 Module Plastic Cover parts price?

    Answer: Submit a fast quote, send VICPAS an email for best price.


    Question: One or multiple module racks?

    Answer: The answer to this query is based on the nature of your application. Reasons for using a single module rack could be:
    • Compact, space-saving module application
    • Central module application
    • Low volume of signals to be processed
    Possible reasons for distribution to multiple module racks:
    • High volume of signals to be processed
    • No more slots available
    Tip: If you choose installation on a single module rack, insert a dummy module to the right side of the CPU (Order No.: 6ES7 321-1BH50-0AA0 Housing). This gives you the option of inserting a second module rack for your application in the future, simply by replacing the dummy module with an interface module and without having to reinstall and rewire the first module rack.


    Common misspellings: 

    6ES731-1EL00-0AA0
    6ES7321-1EL00-0A0
    6ES732-11EL00-0AA0
    bES7321-1EL00-0AA0
    6ES7321-11EL00-0AA0