6ES7332-5HF00-0AB0 Siemens SIMATIC S7 300 Plastic Case
6ES7332-5HF00-0AB0 Siemens SIMATIC S7 300 Plastic Case
6ES7332-5HF00-0AB0 Siemens SIMATIC S7 300 Plastic Case
6ES7332-5HF00-0AB0 Siemens SIMATIC S7 300 Plastic Case
6ES7332-5HF00-0AB0 Siemens SIMATIC S7 300 Plastic Case
6ES7332-5HF00-0AB0 Siemens SIMATIC S7 300 Plastic Case
Model
6ES7332-5HF00-0AB0

Item specifics

Brand
Siemens
Warranty
365 Days
Product Line
Siemens SIMATIC S7-300 Plastic Housing
Supply
Siemens SIMATIC SM 332 analog output module
Siemens S7-300
6ES7332-5HF00-0AB0
Model
6ES7 332-5HF00-0AB0
Number
6ES73325HF000AB0

Review

Description

6ES7332-5HF00-0AB0 Siemens SIMATIC S7-300 Module Housing Repair Replacement


6ES7332-5HF00-0AB0 Siemens SIMATIC S7-300 analog output module SM 332 Plastic Shell Repair Replacement

Analog output module SM 332; AO 8 x 12 bit; (6ES7332-5HF00-0AB0 Housing) Properties
• 8 outputs in one group
• The output can be selected by individual channel
– Voltage output
– Current output
• Resolution 12 bits
• Programmable diagnostics and diagnostic interrupt
• Programmable diagnostic interrupt
• Electrically isolated from the backplane bus interface and load voltage
• Supports parameter reassignment in RUN


S7-300 6ES73325HF000AB0 analog output module SM 332 HMI Case systems are intended for stationary use in locations protected against the weather. The operating conditions surpass the requirements of DIN IEC 60721-3-3.
 Class 3M3 (mechanical requirements)
 Class 3K3 (climatic requirements)


VICPAS supply 6ES7332-5HF00-0AB0 Siemens S7 300 Simatic Module Plastic Case Cover Replacement Part. All of them with VICPAS 365 days warranty and support Urgent Worldwide Shipping.





Specifications:

The table below describes the parameters of the 6ES7332-5HF00-0AB0 Siemens SIMATIC SM 332 analog output modules Case Parts.

Part Number : 6ES7332-5HF00-0AB0
Atmospheric pressure: 1080 to 660 hPa
Temperature: –40 °C to +70°C
Warranty: 365 days Warranty
Product Line: Siemens Simatic S7-300
Dimensions W x H x D (mm): 40 x 120.4 x 110.8
Safety isolation: SELV circuit
Power consumption: 57 W
Power loss: Typ. 9 W
Efficiency: 84 %


Related Siemens Simatic S7-300 Part No. :

Siemens Simatic S7-300 Description Inventory status
6ES7332-5HB01-0AB0 Siemens S7-300 Plastic Shell SM 332 Repair In Stock
6ES7332-5HD01-0AB0 Siemens Simatic S7-300 SM 332 HMI Case Replacement In Stock
6ES7332-5HF00-0AB0 Siemens SIPLUS S7-300 Plastic Case SM 332 Replacement Available Now
6ES7332-5RD00-0AB0 SIMATIC S7 300 SM 332 Plastic Shell Repair Part In Stock
6ES7332-7ND02-0AB0 Siemens S7-300 SM 332 Housing Enclosure Repair Available Now
6ES7334-0CE01-0AA0 Siemens S7-300 SM 334 Plastic Shell Replacement In Stock
6ES7334-0KE00-0AB0 Siemens S7-300 SM 334 Plastic Case Replacement In Stock
6ES7336-4GE00-0AB0 SIMATIC S7 300 SM336 HMI Enclosure Replacement In Stock
6ES7338-4BC01-0AB0 SIMATIC S7 300 Plastic Case SM 338 Replacement Available Now
6ES7350-1AH03-0AE0 Siemens S7-300 SM 350 Housing Repair Replacement Available Now
6ES7370-0AA01-0AA0 SIMATIC S7 300 HMI Case SM 370 Replacement Available Now
6ES7374-2XH01-0AA0 Siemens SIPLUS S7-300 Plastic Case SM 374 Replacement In Stock
6ES7912-0AA00-0AA0 SIEMENS SIMATIC S7-300 Code Plate Replacement Available Now
6GT2002-0GA10 SIEMENS SIMATIC ASM 475 safety protector Repair In Stock
SIPLUS S7 300 PLC Description Inventory status

Siemens SIMATIC S7-300 HMI Manuals PDF Download:

  • 6ES73325HB010AB0 Datasheet
  • 6ES73325HD010AB0 Datasheet
  • 6ES73325HF000AB0 Datasheet
  • SIEMENS SIMATIC S7-300 Getting Started for First Time Users
  • SIEMENS SIMATIC S7-300 Module Data Equipment Manual 2022
  • SIEMENS SIMATIC S7-300 Module Data Manual 2013
  • SIEMENS SIMATIC S7-300 Module Data Manual 2017
  • SIEMENS SIMATIC S7-300 Programmable Controller Hardware and Installation Manual
  • SIEMENS SIMATIC S7-300 Programmable Controller Module Specifications Reference Manual
  • SIEMENS SIMATIC S7-300

  • FAQ:

    Question: When should I use expansion devices?

    Answer: You can use EDs if the number of CU slots is insufficient for your application.
    When using EDs, you might require further power supply modules in addition to the extra module racks and interface modules (IM). When using interface modules, you must ensure compatibility of the partner stations.


    Question: In which situations should I backup the operating system?

    Answer: For example, you should backup the operating system of your system CPU if you want to replace it with a standby CPU and ensure that the operating system is identical in the replacement CPU.
    It is also highly recommended to generate a backup copy of the operating system for emergency situations.


    Question: What is the 6ES7332-5HF00-0AB0 Siemens Simatic S7-300 Module Housing parts price?

    Answer: Submit a fast quote, send VICPAS an email for best price.


    Common misspellings: 

    6ES7332-5HF00-AB0
    6ES7332-HF00-0AB0
    6ES3732-5HF00-0AB0
    6ES7332-5HF00-0A80
    6ESS7332-5HF00-0AB0