Siemens SIMATIC S7 300 6ES7321-1BH50-0AA0 Plastic Cover
Siemens SIMATIC S7 300 6ES7321-1BH50-0AA0 Plastic Cover
Siemens SIMATIC S7 300 6ES7321-1BH50-0AA0 Plastic Cover
Siemens SIMATIC S7 300 6ES7321-1BH50-0AA0 Plastic Cover
Siemens SIMATIC S7 300 6ES7321-1BH50-0AA0 Plastic Cover
Siemens SIMATIC S7 300 6ES7321-1BH50-0AA0 Plastic Cover
Model
6ES7321-1BH50-0AA0

Item specifics

Brand
Siemens
Warranty
365 Days
Product Line
Siemens SIMATIC S7-300 Plastic Shell
Supply
Siemens SIMATIC S7 300 SM 321 digital input module
Siemens S7-300
6ES7321-1BH50-0AA0
Model
6ES7 321-1BH50-0AA0
Number
6ES73211BH500AA0

Review

Description

Siemens SIMATIC S7-300 Module 6ES7321-1BH50-0AA0 Plastic Shell Repair Replacement


Siemens SIMATIC S7-300 SM 321 digital input modules 6ES7321-1BH50-0AA0 Enclosure Repair Replacement

The S7-300 6ES7 321-1BH50-0AA0 Module HMI Case, for example, must not be used without taking additional measures:
 in locations exposed to a high degree of ionizing radiation
 in hostile environments caused, for instance, by
– dust accumulation
– corrosive vapors or gases
– strong electric or magnetic fields
 in installations requiring special monitoring, for example
– elevators
– electrical installations in particularly hazardous areas
An additional measure might be, for instance, installation of the S7-300 6ES7321-1BH50-0AA0 Plastic Case in a cabinet or in a housing.


Digital input module SM 321; DI 16 x DC 24 V; source input; (6ES7321-1BH50-0AA0 Enclosure) Properties
Properties of SM 321 6ES73211BH500AA0 Cover Body; DI 16 x DC 24 V; source input:
● 16 inputs, source input, electrically isolated in groups of 16
● Rated input voltage 24 V DC
● Suitable for switches and 2- /3-/4-wire proximity switches (BEROs)





Specifications:

The table below describes the parameters of the Siemens SIMATIC SM 321 digital input modules 6ES7321-1BH50-0AA0 Plastic Case Parts.

Atmospheric pressure: 1080 to 660 hPa
Part Number : 6ES7321-1BH50-0AA0
Product Line: Siemens Simatic S7-300
Temperature: –40 °C to +70°C
Warranty: 365 days Warranty
Dimensions W x H x D (mm): 40 x 120.4 x 110.8
Efficiency: 84 %
Power consumption: 57 W
Power loss: Typ. 9 W
Safety isolation: SELV circuit


Related Siemens Simatic S7-300 Part No. :

Siemens Simatic S7-300 Description Inventory status
6ES7195-7KF00-0XA0 Siemens S7-300 safety protector HMI Case Replacement In Stock
6ES7321-1BH02-0AA0 Siemens SIPLUS S7-300 Plastic Case SM 321 Replacement Available Now
6ES7321-1BH10-0AA0 SIMATIC S7 300 SM 321 Plastic Shell Repair Part In Stock
6ES7321-1BH50-0AA0 Siemens S7-300 SM 321 Housing Enclosure Repair Available Now
6ES7321-1BL00-0AA0 Siemens S7-300 SM 321 Plastic Shell Replacement In Stock
6ES7321-1CH00-0AA0 Siemens S7-300 SM 321 Plastic Case Replacement In Stock
6ES7321-1CH20-0AA0 SIMATIC S7 300 SM321 HMI Enclosure Replacement In Stock
6ES7321-1EL00-0AA0 SIMATIC S7 300 Plastic Case SM 321 Replacement Available Now
6ES7321-1FF01-0AA0 Siemens S7-300 SM 321 Housing Repair Replacement Available Now
6ES7321-1FF10-0AA0 Siemens S7-300 Plastic Shell SM 321 Repair In Stock
6ES7321-1FH00-0AA0 SIMATIC S7 300 HMI Case SM 321 Replacement Available Now
6ES7321-7BH01-0AB0 Siemens S7-300 SM 321 Housing Replacement In Stock
6ES7321-7RD00-0AB0 SIMATIC S7-300 SM 321 HMI Enclosure Repair Available Now
SIPLUS S7 300 PLC Description Inventory status

Siemens SIMATIC S7-300 HMI Manuals PDF Download:

  • 6AG13211BH022AA0 Datasheet
  • 6AG13211CH202AA0 Datasheet
  • SIEMENS SIMATIC S7-300 Getting Started for First Time Users
  • SIEMENS SIMATIC S7-300 Module Data Equipment Manual 2022
  • SIEMENS SIMATIC S7-300 Module Data Manual 2013
  • SIEMENS SIMATIC S7-300 Module Data Manual 2017
  • SIEMENS SIMATIC S7-300 Programmable Controller Hardware and Installation Manual
  • SIEMENS SIMATIC S7-300 Programmable Controller Module Specifications Reference Manual
  • SIEMENS SIMATIC S7-300

  • FAQ:

    Question: What is the 6ES7321-1BH50-0AA0 Siemens Simatic S7-300 Module Plastic Cover parts price?

    Answer: Submit a fast quote, send VICPAS an email for best price.


    Question: One or multiple module racks?

    Answer: The answer to this query is based on the nature of your application. Reasons for using a single module rack could be:
    • Compact, space-saving module application
    • Central module application
    • Low volume of signals to be processed
    Possible reasons for a distribution to multiple module racks:
    • High volume of signals to be processed
    • No more slots available
    Tip: If you choose installation on a single module rack, insert a dummy module to the right side of the CPU (Order No.: 6ES7 321-1BH50-0AA0 Housing). This gives you the option of inserting a second module rack for your application in the future, simply by replacing the dummy module with an interface module and without having to reinstall and rewire the first module rack.