Schneider ATV212HU30M3X ATV212HU30N4 Operator Panel Keypad
- Model
- ATV212HU30M3X ATV212HU30N4
Item specifics
- Brand
- Schneider
- Warranty
- 365 Days
- Supply
- ATV212HU30M3X Terminal Keypad
- Supply
- ATV212HU30N4 Keypad Membrane Replacement
- Product Line
- Schneider ATV212
Review
Description
Schneider Altivar 212 ATV212HU30M3X ATV212HU30N4 Keypad Membrane Switch Repair

Compatible with Schneider Altivar 212 ATV212HU30M3X ATV212HU30N4 variable speed drives, this replacement membrane keypad from VICPAS delivers industrial-grade durability and intuitive user input. Optimized for asynchronous motor control in environments such as HVAC systems, fan-driven processes, and automated machinery, it ensures seamless integration and long-term performance.
The ATV212HU30M3X ATV212HU30N4 Membrane Keypad connects via the integrated RS485 port and supports Modbus RTU communication, allowing real-time monitoring and adjustment of drive parameters, without additional tools or software. With plug-and-play compatibility and no firmware modification required, this keypad is the cost-effective OEM replacement solution to keep your Altivar 212 drives running smoothly.
VICPAS supplies replacement Schneider ATV212HU30M3X ATV212HU30N4 Membrane Keyboard Keypads with a 12-month warranty and offers urgent worldwide shipping.
Specifications:
The table below describes the parameters of the Altivar 212 Schneider ATV212HU30M3X ATV212HU30N4 Membrane Switch.
Brand: | Schneider |
Motor Power Rating: | 3.0 kW / 4 HP |
Warranty: | 365 Days Warranty |
Output Frequency: | 0.5–200 Hz |
Range of Product: | Altivar 212 |
Operating Temp.: | -10°C to +50°C |
Storage Temp.: | -25 °C to 70 °C |
Relative Humidity: | ≤95% non-condensing |
Related Schneider Altivar 212 series Part No. :
Schneider Altivar 212 | Description | Inventory status |
Schneider ATV212 | Description | Inventory status |
Schneider ATV212 HMI Manuals PDF Download:
FAQ:
Question: Is the keyboard of the ATV212HU30M3X ATV212HU30N4 unit replaceable?
Answer: Yes, the keyboard membrane of ATV212HU30M3X ATV212HU30N4 can be replaceable.
Question: What is RTU mode?
Answer: ATV212 supports RTU mode.
The Modbus RTU frame contains no message header byte, nor end of message bytes.
It is defined as follows:
The data is transmitted in binary code.
CRC16: Cyclic redundancy check parameter.
The end of the frame is detected on a silence greater than or equal to 3 characters.
The master must not introduce a space of more than 3.5 characters in a frame; otherwise the drive may
recognize it as a start of new frame.
Common misspellings:
ATTV212HU30M3X ATV212HU30N4ATV212HU30M3X ATV212HU0N4
ATV212HU30N3X VTV212HU30N4
ATV212HU3oM3X ATV212HU30N4
ATV212HU30M3X ATV212HU30NA