4P3040.00-K12 Membrane Keypad Keyboard
4P3040.00-K12 Membrane Keypad Keyboard
4P3040.00-K12 Membrane Keypad Keyboard
4P3040.00-K12 Membrane Keypad Keyboard
4P3040.00-K12 Membrane Keypad Keyboard
4P3040.00-K12 Membrane Keypad Keyboard
Model
4P3040.00-K12

Item specifics

Brand
B&R
Size
5.7 inch
Warranty
1 Year VICPAS Warranty
Model
B&R Power Panel 41 4P3040.00-K12
Shipping
DHL/FedEx/UPS/TNT/EMS/Aramex /DPEX

Review

Description

B&R Power Panel 41 4P3040.00-K12 Membrane Keypad Keyboard Repair Replacement

Order each part separately is available

Power Panel 41 4P3040.00-K12 Keyboard Membrane

B&R offers the B&R Power Panel 15, 21, 35, and 41 for automation of small to midsize machines and systems. These Power Panels are a combination of an operator panel and a controller in one device. A 4 x 20 character text display, a 3-inch display with 160 x 80 pixels, or a ¼ VGA graphic display can be selected. Each Power Panel is equipped with a powerful PLC CPU including integrated digital or analog I/O. The series PP21 and PP41 panels have an additional six slots for B&R SYSTEM 2003 screw-in modules. An expansion module is offered for the Power Panel 41 which allows the operation of B&R SYSTEM 2005 interface module inserts. The visualization application is created using B&R Automation Studio™. B&R Automation Studio™ is used to program the CPU.


B&R Automation Device Interface (ADI) 4P3040.00-K12 Development Kit Features:
• One Microsoft Visual Basic module with ADI function declarations
• Header files and import libraries for Microsoft Visual C++
• Help files for Visual Basic and Visual C++
• Sample projects for Visual Basic and Visual C++
• ADI DLL (for application testing if no ADI driver is installed)


VICPAS supply B and R Power Panel 41 4P3040.00-K12 Keyboard membrane for repair replacement, make the HMI running. We provide a 365-day VICPAS warranty on most products, which includes most touch screen panel, membrane keypad, protective film, LCD display and protective case shell housing.



Specifications:

The table below describes the parameters of the 4P3040.00-K12 Power Panel 41 Membrane Keypad Switch.

Part Number : 4P3040.00-K12
Product Line: Power Panel 41
Screen diagonal: 5.7 in
Warranty: 365 Days Warranty
Input Power: 24 VDC
Display Type: TFT color
Mounting position: Vertical
Input Type: Keypad
Serial interface Type: RS232
Storage: -20 to 70°C


Related Power Panel 41 Series Part No. :

Power Panel 41 Description Inventory status
4P3040.00-490 B and R Power Panel 41 Membrane Switch Replacement In Stock
4P3040.00-K12 Power Panel 41 B&R HMI Membrane Keyboard Keypad In Stock
4P3040.00-K41 B and R Power Panel 41 Switch Membrane Repair In Stock
4P3040.00-K32 PP41 B&R Membrane Keypad Keyboard Replacement Available Now
4P3040.00-K43 Power Panel 41 B&R Membrane Keypad Switch In Stock
4P3040.00-K47 B and R Power Panel 41 Operator Panel Keypad Available Now
4P3040.00-K50 B&R Power Panel 41 Keypad Membrane Repair Replacement In Stock
4P3040.01-490 B&R Power Panel 41 Membrane Keypad Switch In Stock
4P3040.01-K16 PP41 B and R Membrane Keyboard Keypad Available Now
B and R PP41 Description Inventory status

B&R Power Panel 41 Manuals PDF Download:

  • B&R Power Panel User's Manual
  • B&R Power Panel 15/21/35/41 User's Manual

  • FAQ:

    Question: What is the B&R Power Panel 41 4P3040.00-K12 terminal keypad price?

    Answer: Submit a fast quote, send VICPAS an email for best price.


    Question:How to change the B&R Power Panel 41 4P3040.00-K12 battery?

    Answer: The product design allows the battery to be changed with the Power Panel switched on or off. In some countries, safety regulations do not allow batteries to be changed while the module is switched on.
    How to change the B&R Power Panel 41 4P3040.00-K12 battery?
    The battery is changed as follows:
    • Touch the mounting rail or ground connection (not the power supply!) in order to discharge any electrostatic charge from your body.
    • Remove the cover from the lithium battery holder using a screwdriver.
    • Remove the battery from the holder by pulling the removal strip (don't use uninsulated tools -> risk of short circuiting).
    How to change the B&R Power Panel 41 4P3040.00-K12 battery?
    • The battery should not be held by its edges. Insulated tweezers may also be used for removing the battery.
    How to change the B&R Power Panel 41 4P3040.00-K12 battery?
    • Insert the new battery with correct polarity. The removal strip should be protruding from the battery holder and the "+" side of the battery should be facing downward. In order to be able to remove the battery again in future, the removal strip must protrude from the upper side of the battery.
    • Now wrap the end of the removal strip over the top of the battery and insert it underneath the battery so that it does not protrude from the battery holder.
    How to change the B&R Power Panel 41 4P3040.00-K12 battery?


    Question:How can the Power Panel 41 4P3040.00-K12 lifespan of backlights be extended?

    Answer:
    • Set the display brightness to the lowest value that is still comfortable for the eyes
    • Use dark images
    • Reducing the brightness by 50% can result in an approximate 50% increase of the halfbrightness time.