B&R 4P0420.00-K11 Operator Panel Keypad
B&R 4P0420.00-K11 Operator Panel Keypad
B&R 4P0420.00-K11 Operator Panel Keypad
B&R 4P0420.00-K11 Operator Panel Keypad
B&R 4P0420.00-K11 Operator Panel Keypad
B&R 4P0420.00-K11 Operator Panel Keypad
Model
4P0420.00-K11

Item specifics

Brand
B&R
Warranty
1 Year VICPAS Warranty
Model
B&R Power Panel 21 4P0420.00-K11
Shipping
DHL/FedEx/UPS/TNT/EMS/Aramex /DPEX
Size
5.7 inch

Review

Description

B&R Power Panel 21 4P0420.00-K11 Keyboard Membrane Repair Replacement

Order each part separately is available

Power Panel 21 4P0420.00-K11 Keyboard Membrane

In a distributed system, two or more Power Panel devices (PP21, PP41) are connected to each other over a CAN bus. Control programs run on each Power Panel. The sensors and actuators are connected to the integrated and insertable inputs and outputs as well as the remote CAN bus stations.


B&R Automation Runtime guarantees a uniform runtime environment for Automation Studio programs on all target systems. This ensures uniform programming and operation on all devices. Automation Runtime possesses a multitasking operating system adapted specially for use with control technology. The cycle time for your application can be separated among several task classes. Automation Runtime ensures that all application programs are executed within defined time periods, proving itself to be a configurable, deterministic real-time multitasking system. An extensive project can be divided into small individual tasks. This way of working increases modularity and makes it much easier to maintain projects.



  Contact Best Price  


Specifications:

The table below describes the parameters of the 4P0420.00-K11 Power Panel 21 Membrane Keyboard Keypad.

Part Number : 4P0420.00-K11
Product Line:Power Panel 21
Screen diagonal5.7 in
Warranty: 365 Days Warranty
Input Power24 VDC
Display Type:TFT color
Mounting position: Vertical
Input Type: Keypad
Serial interface Type:RS232
Storage -20 to 70°C


Related Power Panel 21 Series Part No. :

Power Panel 21 Description Inventory status
4P0420.00-490 B&R Power Panel 21 Membrane Keyboard Keypad In Stock
4P0420.00-K08 PP21 B and R Operator Panel Keypad Repair Available Now
4P0420.00-K11 B&R Power Panel 21 Membrane Keypad Switch Repair In Stock
B and R PP21 Description Inventory status

B&R Power Panel 21 Manuals PDF Download:

  • B&R Power Panel User's Manual
  • B&R Power Panel 15/21/35/41 User's Manual

  • FAQ:

    Question:What are the functions of B&R Automation Device Interface (ADI) - Control Center?

    Answer: The functions provided by the Automation Device Interface (ADI) - Control Center vary according to the device series.
    To carry out a firmware upgrade, the following steps should be taken:
    • Changing display-specific parameters
    • Reading device-specific keys
    • Updating the key configuration
    • Enabling device-specific LEDs on a membrane keypad or keys
    •Reading and calibrating control devices (e.g. key switches, handwheels, joysticks, potentiometers)
    • Reading temperatures, fan speeds, statistical data and switch settings
    • Reading operating hours (power-on hours)
    • Reading user and factory settings
    • Reading software versions
    • Updating and backing up BIOS and firmware
    • Creating reports about the current system (support assistance)
    • Setting the SDL equalizer value when adjusting SDL cables
    • Changing the user serial ID


    Question:How can Power Panel 21 4P0420.00-K11 screen burn-in be avoided?

    Answer:
    • By constantly changing between static and dynamic images
    • By avoiding excessive brightness differences between foreground and background elements
    • By using colors with similar brightness
    • By using complementary colors in follow-up images
    • By using a screensaver


    Question:What causes B&R 4P0420.00-K11 image sticking?

    Answer:
    • Static images
    • Screensaver not enabled
    • Sharp contrast transitions (e.g. black / white)
    • High ambient temperatures
    • Operation outside of the specifications


    Common misspellings: 

    4P040.00-K11

    4P420.00-K11

    4P0420.00-Kll

    4P042O.00-K11

    4P0420.00--K11