Panelview Plus 7 2711P-T10C21D8S-B Touchscreen Panel
Panelview Plus 7  2711P-T10C21D8S-B Touchscreen Panel
Panelview Plus 7  2711P-T10C21D8S-B Touchscreen Panel
Panelview Plus 7  2711P-T10C21D8S-B Touchscreen Panel
Panelview Plus 7  2711P-T10C21D8S-B Touchscreen Panel
Panelview Plus 7  2711P-T10C21D8S-B Touchscreen Panel
Model
2711P-T10C21D8S-B

Item specifics

Warranty
365 Days
Brand
Rockwell Automation Allen Bradley
Product Line
Panelview Plus 7
Supply
Panelview Plus 7 HMI Touchscreen
Size
10.4 inch
model
2711P-T10C21D8S-B
Parts
Touchscreen Panel Glass Protective Film

Review

Description

2711P-T10C21D8S-B Panelview Plus 7 Touch Screen Panel, Protective Films Overlay, and LCD Display Repair Replacement

Order each part separately is available

2711P-T10C21D8S-B Panelview Plus 7 Touch Screen Panel Protective Film LCD Display Screen Repair Replacement
2711P-T10C21D8S-B Panelview Plus 7 Touch Screen Panel Protective Film LCD Display Screen Repair Replacement


PanelView Plus 7 Standard and Performance Models
 Lead product for new applications
 Extends our portfolio with more display sizes and certifications
 Reflects our commitment to application longevity
Same FactoryTalk View software across all PanelView Plus product lines


The Standard and Performance clamps look different:
 The clamps for the PanelView Plus 7 line are designed to create the right amount of clamping pressure around the unit with breakaway tabs to prevent over torqueing. Each clamp is two sided, so if you break one side, you can use the other.
 The system is designed to allow customers to mount the terminals with no tools. See product literature for the clamping sequence.
 At full release, there will be two different clamp styles. One for Standard (Grey) and one for Performance (Black). They are not meant to be used cross platform because the Performance (Black) clamps allow for a higher clamping torque and can crack the bezel on the Standard terminal.
The PanelView Plus 7 Performance stainless steel models use 2711P-RTMC clamps.


The PanelView™ Plus 7 Standard terminals 2711P-T10C21D8S-B are operator interface devices. 2711P-T10C21D8S-B monitor and control devices that are attached to ControlLogix® 5570 and CompactLogix™ 5370 controllers on an EtherNet/IP network. Animated graphic and text displays provide operators a view into the operating state of a machine or process. Operators interact with the control system by using touch screen input.


FactoryTalk ViewPoint software, an add-on to FactoryTalk View Studio software, allows plant managers, production supervisors, system integrators, and other key stakeholders to view and control real-time plant floor operations remotely from a web browser. FactoryTalk ViewPoint enabled displays are fully scalable and animated in the browser. The remote user can also view displays that are not the active display of the terminal.



  Contact Best Price  


Specifications:

The table below describes the parameters of the Panelview Plus 7 2711P-T10C21D8S-B Operator Panel Parts

Part Number : 2711P-T10C21D8S-B
Display Size: 10.4 inches
Display ColorAmber
Warranty: 365 days Warranty
Product Line:Panelview Plus 7
Input Type:Touchscreen
Mounting position: vertical
Communication: Ethernet and RS-232
Communication:ControlNet
Software FactoryTalk


Related Allen Bradley Panelview Plus 7 Terminals Part No. :

PanelView Plus 7 HMI Description Inventory status
2711P-T9W21D8S PanelView Plus 7 Touch Screen Panel Glass Overlay LCD Display In Stock
2711P-T9W21D8S-A PanelView Plus 7 Touch Panel Glass Front Overlay LCD Screen Available Now
2711P-T9W21D8S-B Allen Bradley Panel Plus 7 Touchscreen Protective Film LCD Display In Stock
2711P-T9W22D8S Allen Bradley Panel View Plus 7 Touch Screen Overlay Display In Stock
2711P-T9W22D8S-A PanelView Plus 7 Touch Panel Front Overlay LCD Display Screen In Stock
2711P-T9W22D8S-B PanelView Plus 7 Touch Panel Protective Film LCD Display Panel In Stock
2711P-T10C21D8S PanelView Plus 7 Touch Membrane Overlay LCD Display Repair Available Now
2711P-T10C21D8S-A Allen Bradley PanelView Plus 7 HMI Touchscreen Front Film LCD Display In Stock
2711P-T10C21D8S-B PanelView Plus 7 Touchscreen Membrane Switch Overlay LCD Screen Available Now
2711P-T10C22D8S AB Panel View Plus 7 HMI Panel Glass Overlay LCD Display In Stock
2711P-T10C22D8S-A Allen Bradley Panel View Plus 7 Touchscreen Film LCD Display In Stock
2711P-T10C22D8S-B PanelView Plus 7 Touch Glass Front Overlay LCD Display Panel In Stock
AB PanelView Plus 7 Description Inventory status

AB Panelview Plus 7 Manuals PDF Download:

  • PanelView Plus 7 HMI Standard Terminals 2711P-T10C21D8S-B Manuals
  • PanelView Plus 7 Allen Bradley Standard Terminals Technical Data
  • AB PanelView Plus 7 Standard Terminals 2711P-T10C21D8S-B User Manuals
  • PanelView Plus 7 Operator Interface Standard and Performance


  • FAQ:

    Question: How to disable the Allen Bradley PanelView Plus 7 Standard Terminals 2711P-T10C21D8S-B Screen Cursor?

    Answer:The terminal 2711P-T10C21D8S-B has a screen cursor that you can disable or enable.
    1. Press Terminal Settings, then choose Display>Cursor.
    2. To disable or enable the cursor, press Enable Cursor.
    3. To exit and return to terminal settings, press OK.


    Question: How to edit the device address of the 2711P-T10C21D8S-B controller?

    Answer:
    1. Press Terminal Settings, then choose Networks and Communications>RSLinx Enterprise Communications.
    How to edit the device address of the 2711P-T10C21D8S-B controller?
    2. Select the controller in the tree.
    3. To view the device name and current address, press Edit Device.
    4. To modify the address, press Device Address. The input panel opens with the current address.
    5. Enter the address in the input panel and press Enter.
    6. Press OK.


    Question: What is the size of Allen Bradley 2711P-T10C21D8S-B Toucshcreen Panel Glass?

    Answer:The PanelView Plus 7 2711P-T10C21D8S-B Touch Screen Panel is 10.4-inch.


    Question:How to view or enter an IP address for terminal 2711P-T10C21D8S-B?

    Answer:
    1. Press Terminal Settings, then choose Networks and Communications>Network Connections>Network Adapters.
    How to view or enter an IP address for terminal 2711P-T10C21D8S-B?
    2. To view or modify the IP address, press IP Address.
    3. To enable or disable DHCP assignment of addresses, press Use DHCP.
    • If DHCP is enabled or set to Yes, IP addresses are automatically assigned to newly attached devices on the network.
    • If DHCP is disabled or set to No, you can manually enter the IP address. Press IP Address, Subnet Mask, and Gateway to enter IP formatted addresses.
    How to view or enter an IP address for terminal 2711P-T10C21D8S-B?
    4. Press OK when done. If prompted, reset the device from the FactoryTalk View ME Station dialog box.
    5. Press Close.



    Common misspellings: 

    2711PT10C21D8S-B
    2711P-T10C2D8S-B
    2711P-T10C21D8S-
    2711-PT10C21D8S-B
    2711P-T10C21D8-SB
    27211P-T10C21D8S-B
    27111P-T10C21D8S-B
    2711P-T10C21DD8S-B