2711P-K10C6B1 Membrane Keypad Keyboard Repair
2711P-K10C6B1 Membrane Keypad Keyboard Repair
2711P-K10C6B1 Membrane Keypad Keyboard Repair
2711P-K10C6B1 Membrane Keypad Keyboard Repair
2711P-K10C6B1 Membrane Keypad Keyboard Repair
2711P-K10C6B1 Membrane Keypad Keyboard Repair
Model
2711P-K10C6B1

Item specifics

Warranty
180 Days
Brand
Rockwell Automation Allen Bradley
Product Line
Panelview Plus 1000
Supply
Panelview Plus 1000 Terminals Membrane keypad
Size
10.4 inch
model
2711P-K10C6B1
Parts
Keypad Switch Front Cover LCD Display

Review

Description

2711P-K10C6B1 Panelview Plus 1000 Terminals Membrane Keypad LCD Display Housing Repair

Order each part separately is available

2711P-K10C6B1 Panelview 1000 Terminals Membrane Keypad, Protection Board, Label, Plastic Shell, LCD Display, Gasket and Mounting Clips Repair Replacement


The obsolete 2711P-K10C6B1 PanelView Plus 1000 Terminal is an operator terminal that allows the user to interface with their machine. This HMI has a 10.4 in. Color Display screen. 2711P-K10C6B1 PanelView Plus is ideal for applications with a need to observe, manipulate, and display information graphically. This allows operators to quickly understand the status of their application.


The most common 2711P-K10C6B1 Series are: Ser A, B, C, D, and F. The most common firmware for this Panelview Plus include 3.13-4.48. Each module has a specific and unique IP address. This port has an RJ45, 10/100Base-T connector for network communication and enables MDI/MDI-X connections. The parameters can be downloaded with the application.


This 2711P-K10C6B1 Keypad unit has an internal backlight replacement part number of 2711P-RL10C. This 2711P-K10C6B1 unit is powered using 18-32 Volt DC power. The approximate shipping weight and dimensions are 10 lbs. and 18 x 14 x 8 in. EtherNet/IP (Ethernet Industrial Protocol) is an open industrial network that supports real time I/O messaging, as well as message exchange.


The EtherNet/IP screen displays and allows the user to modify some of the EtherNet/IP communication settings for a PanelView terminal.EtherNet/IP (Ethernet Industrial Protocol) is an open industrial network that supports real time I/O messaging, as well as message exchange. The EtherNet/IP screen displays and allows the user to modify some of the EtherNet/IP communication settings for a PanelView terminal. If another port is required, the 2711P-RN20 Ethernet communication module is available for the 700 to 1500 Panelview Plus terminals. The Ethernet port connects to a controller on an EtherNet/IP network by using both the network and standard Ethernet connections. This port can work with application transfers and printing as well.





Specifications:

The table below describes the parameters of the Panelview Plus 1000 2711P-K10C6B1 terminals Parts.

Part Number: 2711P-K10C6B1
Display Size: 10.4 inches
Display Color: Amber
Warranty: 180 days Warranty
Product Line: Panelview Plus 1000
Input Type: Keypad
Mounting Position: vertical
Communication: Ethernet and RS-232
Language: Worldwide
Software: Talk View Machine Edition


Related Allen Bradley Panelview Plus 1000 Terminals Part No. :

PanelView Plus 1000 HMI Description Inventory status
2711P-K10C4A1 PanelView Plus 1000 Membrane Keyboard LCD Display Plastic Shell Repair Kit In Stock
2711P-K10C4A2 PanelView Plus 1000 Membrane Keyboard Keypad LCD Display Panel Enclosure Available Now
2711P-K10C4A6 Allen Bradley Panel Plus 1000 Membrane Keypad LCD Screen Plastic Cover Body In Stock
2711P-K10C4A7 Allen Bradley Panel View Plus 1000 Keypad LCD Display Enclosure Repalcement In Stock
2711P-K10C4B1 PanelView Plus 1000 Membrane Switch LCD Display Screen Plastic Cover Body In Stock
2711P-K10C4B2 PanelView Plus 1000 Membrane Keyboard Keypad LCD Display Screen HMI Case In Stock
2711P-K10C4D1 PanelView Plus 1000 Membrane Keypad Switch LCD Display Housing Repair Kit Available Now
2711P-K10C4D2 Allen Bradley PanelView Plus 1000 Operator Panel Keypad LCD Screen HMI Case In Stock
2711P-K10C4D6 PanelView Plus 1000 Operator Keyboard LCD Display Housing Replacement Available Now
2711P-K10C4D7 Allen Bradley Panel View Plus 1000 Keyboard Membrane LCD Screen Plastic Shell In Stock
2711P-K10C6A1 Allen Bradley Panel View Plus 1000 Keypad Membrane LCD Display Housing In Stock
2711P-K10C6A2 PanelView Plus 1000 Switch Membrane Enclosure LCD Display Panel Replacement In Stock
2711P-K10C6A6 PanelView Plus 1000 Plastic Shell LCD Display Screen Keypad Repair Kit Available Now
2711P-K10C6A7 Allen Bradley PanelView Plus 1000 Membrane Keyboard LCD Display Housing In Stock
2711P-K10C6B1 PanelView Plus 1000 Membrane Keyboard Keypad LCD Screen HMI Case Repair Available Now
2711P-K10C6B2 Allen Bradley Panel View Plus 1000 Operator Panel Keypad LCD Display Enclosure In Stock
AB PanelView Plus 1000 Description Inventory status

AB Panelview Plus 1000 Manuals PDF Download:

  • 2711P-K10C6B1 Terminals Manuals
  • Allen Bradley Panelview Plus 1000 Terminals Manuals
  • PanelView Plus 700 to 1500 and PanelView Plus Compact 1000 Terminals and Display Modules
  • Panelview Plus 1000 battery replacement Installation Instructions


  • FAQ:

    Question: What is the size of 2711P-K10C6B1 Membrane Keyboard?

    Answer: The 2711P-K10C6B1 keypad is 10.4-inch.


    Question: How to delete Log Files of PanelView Plus 1000 the from terminal?

    Answer: You can delete log files, alarm history files, and alarm status files from the System Default location on the terminal.
    1. Select Terminal Settings>File Management>Delete Files>Delete Log Files. You are asked to confirm the deletion of the files.
    Do you want to delete all of the Factory Talk View ME Station Log Files?
    2. Select Yes or No. Log files not located in the System Default location will not be deleted.


    Question: How to Replace Battery in PanelView Plus 1000 2711P-K10C6B1 Terminals?

    Answer: Follow these steps to replace the battery in the logic module of any PanelView Plus terminal with a 1000 display.

    1. Disconnect power from the terminal.

    2. Disconnect all power and communication cables.

    3. Detach the communication module, if attached, from the logic module by removing the four screws.

    Replace Battery in PanelView Plus 1000 Terminals
    4. Loosen the captive screws that secure the logic module to the display module and carefully lift the logic module away from the back of the display.

    5. Locate the battery on the circuit board.

    6. Remove the battery by lifting the side of the battery.

    Repair Battery in Allen Bradley PanelView Plus HMI
    7. Insert the new battery with the positive polarity (+) facing up.


    Common misspellings: 

    271P-K10C6B1
    2711-K10C6B1
    2711P-K0C6B1
    2711PK10C6B1
    7211P-K10C6B1
    2711PK-10C6B1
    271P1-K10C6B1
    2711-PK10C6B1
    2711P-KK10C6B1
    2711P--K10C6B1