2711P-K10C4B1 Membrane Keypad Keyboard Repair
2711P-K10C4B1 Membrane Keypad Keyboard Repair
2711P-K10C4B1 Membrane Keypad Keyboard Repair
2711P-K10C4B1 Membrane Keypad Keyboard Repair
2711P-K10C4B1 Membrane Keypad Keyboard Repair
2711P-K10C4B1 Membrane Keypad Keyboard Repair
Model
2711P-K10C4B1

Item specifics

Warranty
180 Days
Brand
Rockwell Automation Allen Bradley
Product Line
Panelview Plus 1000
Supply
Panelview Plus 1000 Terminals Membrane keypad
Size
10.4 inch
model
2711P-K10C4B1
Parts
Keypad Switch Enclosure LCD Display

Review

Description

2711P-K10C4B1 Panelview Plus 1000 Terminals Membrane Keypad LCD Display Plastic Case Repair

Order each part separately is available

2711P-K10C4B1 Panelview 1000 Terminals Membrane Keypad, Protection Board, Label, Plastic Case, LCD Display, Gasket and Mounting Clips Repair Replacement


The Panelview Plus 1000 2711P-K10C4B1 keypad enables the user to connect using FactoryTalk View Machine Edition software and a ControlNet communication port with a 1747-KFC15A communication cable(s). The user is able to control the operator terminal using the Keypad/Touchscreen to input information and data. This unit is powered using 18-32 VDC power. This Panelview Plus has the following internal memory: 256 MB. This unit has an internal backlight replacement part number of 2711P-RL10C.


This 2711P-K10C4B1 unit has an internal backlight replacement part number of 2711P-RL10C. This 2711P-K10C4B1 unit is powered using 18-32 Volt DC power. The approximate shipping weight and dimensions are 10 lbs. and 18 x 14 x 8 in. EtherNet/IP (Ethernet Industrial Protocol) is an open industrial network that supports real time I/O messaging, as well as message exchange. The EtherNet/IP screen displays and allows the user to modify some of the EtherNet/IP communication settings for a PanelView terminal.


The ControlNet terminals support symbolic CIP addressing when communicating with a ControlLogix system. Every terminal offers a Network Access port for local access to the ControlNet network. Application files are easily downloaded or uploaded using PanelBuilder32 over the ControlNet link, directly via the on-board RS-232 printer port, or with a PC memory card.


VICPAS supply panelview Plus 2711P-K10C4B1 membrane keyboard switch, Protection Board, Label, Plastic Cover Body, LCD Screen, Mounting Clips and Gasket. All of them with VICPAS 180 days warranty and support Urgent Worldwide Shipping.





Specifications:

The table below describes the parameters of the Panelview Plus 1000 2711P-K10C4B1 terminals Parts.

Part Number: 2711P-K10C4B1
Display Size: 10.4 inches
Display Color: Amber
Warranty: 180 days Warranty
Product Line: Panelview Plus 1000
Input Type: Keypad
Mounting Position: vertical
Communication: Ethernet and RS-232
Language: Worldwide
Software: Talk View Machine Edition


Related Allen Bradley Panelview Plus 1000 Terminals Part No. :

PanelView Plus 1000 HMI Description Inventory status
2711P-K10C4A1 PanelView Plus 1000 Membrane Keyboard LCD Display Plastic Shell Repair Kit In Stock
2711P-K10C4A2 PanelView Plus 1000 Membrane Keyboard Keypad LCD Display Panel Enclosure Available Now
2711P-K10C4A6 Allen Bradley Panel Plus 1000 Membrane Keypad LCD Screen Plastic Cover Body In Stock
2711P-K10C4A7 Allen Bradley Panel View Plus 1000 Keypad LCD Display Enclosure Repalcement In Stock
2711P-K10C4B1 PanelView Plus 1000 Membrane Switch LCD Display Screen Plastic Cover Body In Stock
2711P-K10C4B2 PanelView Plus 1000 Membrane Keyboard Keypad LCD Display Screen HMI Case In Stock
2711P-K10C4D1 PanelView Plus 1000 Membrane Keypad Switch LCD Display Housing Repair Kit Available Now
2711P-K10C4D2 Allen Bradley PanelView Plus 1000 Operator Panel Keypad LCD Screen HMI Case In Stock
2711P-K10C4D6 PanelView Plus 1000 Operator Keyboard LCD Display Housing Replacement Available Now
2711P-K10C4D7 Allen Bradley Panel View Plus 1000 Keyboard Membrane LCD Screen Plastic Shell In Stock
2711P-K10C6A1 Allen Bradley Panel View Plus 1000 Keypad Membrane LCD Display Housing In Stock
2711P-K10C6A2 PanelView Plus 1000 Switch Membrane Enclosure LCD Display Panel Replacement In Stock
2711P-K10C6A6 PanelView Plus 1000 Plastic Shell LCD Display Screen Keypad Repair Kit Available Now
2711P-K10C6A7 Allen Bradley PanelView Plus 1000 Membrane Keyboard LCD Display Housing In Stock
2711P-K10C6B1 PanelView Plus 1000 Membrane Keyboard Keypad LCD Screen HMI Case Repair Available Now
2711P-K10C6B2 Allen Bradley Panel View Plus 1000 Operator Panel Keypad LCD Display Enclosure In Stock
AB PanelView Plus 1000 Description Inventory status

AB Panelview Plus 1000 Manuals PDF Download:

  • 2711P-K10C4B1 Terminals Manuals
  • Allen Bradley Panelview Plus 1000 Terminals Manuals
  • PanelView Plus 700 to 1500 and PanelView Plus Compact 1000 Terminals and Display Modules
  • Panelview Plus 1000 battery replacement Installation Instructions


  • FAQ:

    Question: How to access panelview plus 1000 configuration mode?

    Answer: Your PanelView Plus 1000 device has onboard software, FactoryTalk View ME Station, to perform and configure terminal operations. When you reset or start the terminal, you automatically enter Configuration mode, unless your .MER application is automatically set to run on startup.

    To access Configuration mode from a running application, press the Goto Configuration Mode button. This button is added to the application screen in FactoryTalk View Studio. The application stops running but is still loaded


    IMPORTANT To access Configuration mode from a running application, you must add a Goto Configuration Mode button to an application screen.

    On PanelView Plus 1000 Terminals HMI device, you can enter Configuration mode from the Start menu or the desktop.

     Select Start>Programs>Rockwell Software>FactoryTalk View>FactoryTalkView ME Station.
     Select the FactoryTalk View ME Station icon on the desktop.

    How to access panelview plus 1000 configuration mode?

    • Load Application (F1): Opens another screen where you can select an application to load. Once loaded, the application name will appear under Current Application.

    • Run Application (F2): Runs the .mer application displayed under Current Application. An application must be loaded before you can run it. Application Settings (F3) Opens a menu of application-specific configuration settings. Terminal Settings (F4) Opens a menu of options to configure non-application, specific terminal settings for the PanelView Plus device.

    • Delete Log Files Before Running (F5): Toggles between Yes and No. If you select Yes, all data log files, alarm history and alarm status file will be deleted before the application is run. If you select No, log files are not deleted first.

    • Reset (F7): Resets the terminal. The action that occurs on startup for PanelView Plus CE devices depends on whether you defined shortcut paths in the Windows Startup folder. On other PanelView Plus devices, the action on startup depends on configured startup options.
    • Exit (F8): Exits Configuration mode.


    Question: What is the size of 2711P-K10C4B1 Membrane Keyboard?

    Answer: The 2711P-K10C4B1 keypad is 10.4-inch.


    Question: What is the 2711P-K10C4B1 Panelview Plus 1000 HMI parts price?

    Answer: Submit a fast quote, send VICPAS an email for best price.


    Common misspellings: 

    2711P-K1oC4B1
    2711P-10C4B1
    2711P-K10C4Bl
    711P-K10C4B1
    271P-K10C4B1
    2711-K10C4B1
    2711PK10C4B1
    27l1P-K10C44B1
    271lP-K110C4B1
    2711P-K01C4B1