Membrane keyboard for 2711P-K10C4A8 membrane keypad switch
Membrane keyboard for 2711P-K10C4A8 membrane keypad switch
Membrane keyboard for 2711P-K10C4A8 membrane keypad switch
Membrane keyboard for 2711P-K10C4A8 membrane keypad switch
Membrane keyboard for 2711P-K10C4A8 membrane keypad switch
Membrane keyboard for 2711P-K10C4A8 membrane keypad switch
Model
2711P-K10C4A8

Item specifics

Warranty
180 Days
Brand
Allen Bradley
Product Line
Panelview Plus 6
Supply
Panelview Plus 6 Terminals Membrane keypad
Size
10.4 inch
model
2711P-K10C4A8
Parts
Keypad Switch Repair LCD Display

Review

Description

2711P-K10C4A8 Panelview Plus 6 Terminals Membrane Keypad Plastic Cover Body LCD Display Repair

Order each part separately is available

2711P-K10C4A8 Panelview 6 Terminals Membrane Keypad, Protection Board, Label, Plastic Cover Body, LCD Screen, Gasket and Mounting Clips Repair Replacement


The Panelview Plus 6 2711P-K10C4A8 enables the user to connect using FactoryTalk View Machine Edition software and a ControlNet communication port with a 1747-KFC15A communication cable(s). The user is able to control the operator terminal using the Keypad/Touchscreen to input information and data. This unit is powered using 18-32 VDC power. This Panelview Plus has the following internal memory: 256 MB. This unit has an internal backlight replacement part number of 2711P-RL10C.


This 2711P-K10C4A8 unit has an internal backlight replacement part number of 2711P-RL10C. This 2711P-K10C4A8 unit is powered using 18-32 Volt DC power. The approximate shipping weight and dimensions are 10 lbs. and 18 x 14 x 8 in. EtherNet/IP (Ethernet Industrial Protocol) is an open industrial network that supports real time I/O messaging, as well as message exchange. The EtherNet/IP screen displays and allows the user to modify some of the EtherNet/IP communication settings for a PanelView terminal.


The ControlNet terminals support symbolic CIP addressing when communicating with a ControlLogix system. Every terminal offers a Network Access port for local access to the ControlNet network. Application files are easily downloaded or uploaded using PanelBuilder32 over the ControlNet link, directly via the on-board RS-232 printer port, or with a PC memory card.


VICPAS supply panelview Plus 6 2711P-K10C4A8 membrane keyboard switch, Protection Board, Label, Plastic Cover, Gasket, Mounting Clips and LCD Display Screen. All of them with VICPAS 180 days warranty and support Urgent Worldwide Shipping.





Specifications:

The table below describes the parameters of the Panelview Plus 6 2711P-K10C4A8 terminals Parts.

Part Number: 2711P-K10C4A8
Display Size: 10.4 inches
Display Color: Amber
Warranty: 180 days Warranty
Product Line: Panelview Plus 6
Input Type: Keypad
Mounting Position: vertical
Communication: Ethernet and RS-232
Language: Worldwide
Software: Talk View Machine Edition


Related Allen Bradley Panelview Plus 6 Terminals Part No. :

PanelView Plus 6 HMI Description Inventory status
2711P-K6M20A8 Allen Bradley Panel Plus 6 Membrane Keypad LCD Display Plastic Case In Stock
2711P-K6M20D8 Allen Bradley Panel View Plus 6 Keypad LCD Screen Cover Replacement Available Now
2711P-K7C4A8 PanelView Plus 6 Membrane Switch LCD Display Plastic Shell Replacement In Stock
2711P-K7C4A9 PanelView Plus 6 Membrane Keyboard Keypad LCD Screen HMI Case In Stock
2711P-K7C4D8 PanelView Plus 6 Membrane Keypad Switch LCD Display Housing Repair In Stock
2711P-K7C4D9 Allen Bradley PanelView Plus 6 Operator Panel Keypad LCD Display Enclosure In Stock
2711P-K10C4A8 PanelView Plus 6 Operator Keyboard LCD Display Plastic Case Replacement Available Now
2711P-K10C4A9 Allen Bradley Panel View Plus 6 Keyboard Membrane LCD Display Case In Stock
2711P-K10C4D8 PanelView Plus 6 Membrane Keyboard Repair Kit Plastic Shell LCD Display Available Now
2711P-K10C4D9 PanelView Plus 6 Membrane Keyboard Keypad LCD Display Case Repair In Stock
2711P-K12C4A8 Allen Bradley Panel View Plus 6 Keypad Plastic Case LCD Display Screen In Stock
2711P-K12C4A9 PanelView Plus 6 Switch Membrane HMI Case LCD Display Screen In Stock
2711P-K12C4D8 PanelView Plus 6 Touch Screen Keypad Front Cover LCD Display Panel Available Now
2711P-K12C4D9 Allen Bradley PanelView Plus 6 Membrane Keyboard Plastic Case LCD Screen In Stock
2711P-K15C4A8 PanelView Plus 6 Membrane Keyboard Keypad Housing LCD Display Screen Available Now
2711P-K15C4A9 Allen Bradley Panel View Plus 6 Operator Panel Keypad Front Cover LCD Display In Stock
2711P-K15C4D8 Allen Bradley Panel View Plus 6 Keypad Plastic Shell LCD Screen Repair In Stock
2711P-K15C4D9 PanelView Plus 6 Membrane Switch Plastic Case LCD Display Replacement In Stock
AB PanelView Plus 6 Description Inventory status

AB Panelview Plus 6 Manuals PDF Download:

  • 2711P-K10C4A8 Terminals Manuals
  • Allen Bradley Panelview Plus 6 Terminals Manuals
  • PanelView Plus 700 to 1500 and PanelView Plus Compact 6 Terminals and Display Modules
  • Panelview Plus 6 battery replacement Installation Instructions


  • FAQ:

    Question: How to access panelview plus 6 configuration mode?

    Answer : Your PanelView Plus 6 device has onboard software, FactoryTalk View ME Station, to perform and configure terminal operations. When you reset or start the terminal, you automatically enter Configuration mode, unless your.MER application is automatically set to run on startup.

    To access Configuration mode from a running application, press the Goto Configuration Mode button. This button is added to the application screen in FactoryTalk View Studio. The application stops running but is still loaded


    IMPORTANT To access Configuration mode from a running application, you must add a Goto Configuration Mode button to an application screen.

    On PanelView Plus 6 Terminals HMI device, you can enter Configuration mode from the Start menu or the desktop.

     Select Start>Programs>Rockwell Software>FactoryTalk View>FactoryTalkView ME Station.
     Select the FactoryTalk View ME Station icon on the desktop.

    How to access panelview plus 6 configuration mode?

    • Load Application (F1): Opens another screen where you can select an application to load. Once loaded, the application name will appear under Current Application.

    • Run Application (F2): Runs the .mer application displayed under Current Application. An application must be loaded before you can run it. Application Settings (F3) Opens a menu of application-specific configuration settings. Terminal Settings (F4) Opens a menu of options to configure non-application, specific terminal settings for the PanelView Plus device.

    • Delete Log Files Before Running (F5): Toggles between Yes and No. If you select Yes, all data log files, alarm history and alarm status files will be deleted before the application is run. If you select No, log files are not deleted first.

    • Reset (F7): Resets the terminal. The action that occurs on startup for PanelView Plus CE devices depends on whether you defined shortcut paths in the Windows Startup folder. On other PanelView Plus devices, the action on startup depends on configured startup options.
    • Exit (F8): Exits Configuration mode.


    Question: What is the size of 2711P-K10C4A8 Membrane Keyboard?

    Answer: The 2711P-K10C4A8 keypad is 10.4-inch.


    Question: What is the 2711P-K10C4A8 Panelview Plus 6 HMI parts price?

    Answer: Submit a fast quote, send VICPAS an email for best price.


    Common misspellings: 

    2711P-K1oC4A8
    2711P-K1C4AB
    711P-K10C4A8
    271P-K10C4A8
    2711-K10C4A8
    2711PK10C4A8
    27l1P-K10C44A8
    271lP-K110C4A8
    2711P-K01C4A8