2711P-B12C10D6 Touchscreen Keypad Switch LCD Display Enclosure
2711P-B12C10D6 Touchscreen Keypad Switch LCD Display Enclosure
2711P-B12C10D6 Touchscreen Keypad Switch LCD Display Enclosure
2711P-B12C10D6 Touchscreen Keypad Switch LCD Display Enclosure
2711P-B12C10D6 Touchscreen Keypad Switch LCD Display Enclosure
2711P-B12C10D6 Touchscreen Keypad Switch LCD Display Enclosure
Model
2711P-B12C10D6

Item specifics

Warranty
365 Days
Brand
Rockwell Automation Allen Bradley
Product Line
Panelview Plus 1250
Supply
Panelview Plus 1250 Terminals Membrane keypad
Size
12.1 inch
model
2711P-B12C10D6
Parts
Touchscreen Panel Glass Membrane Switch

Review

Description

2711P-B12C10D6 Panelview Plus 1250 Touch Screen Panel, Membrane Keypad Switch, HMI Case, LCD Display

Order each part separately is available

2711P-B12C10D6 Panelview Plus 1250 Membrane keypad switch, Label, LCD Display Panel, Housing, Gasket and Mounting Clips Repair Replacement

The PanelView Plus 1250 2711P-B12C10D6 terminals are operating and display devices that run RSView Machine Edition (V3.0 or later). Features include:
• graphic color display modules with keypad, touch screen, or keypad & touch screen support
• analog resistive touch screen
• field replaceable bezels
• modular communications for easy add-on capability
• memory expansion modules for field upgrades to 256 MB
• Compact Flash Card slot supports Type I/II Compact Flash Cards
• USB ports provides connections for keyboard/mouse/printer support
• Ethernet and serial communications
• IrDA infrared data port
• same panel cutouts as the PanelView Standard and PanelView Enhanced terminals


VICPAS supply panelview Plus 1250 2711P-B12C10D6 Touchscreen Panel, Membrane Keypad Switch, Label, Plastic Shell, LCD Display, Gasket and Mounting Clips. All of them with VICPAS 365-day warranty and support Urgent Worldwide Shipping.


The 2711P-B12C10D6 features a 12.1-inch full-color display module and comes pre-installed with touch input features. These touchscreen features can be used to provide fast and accurate input on the functions provided by the display terminal, as well as to navigate through the various menus that offer the user access to these particular functions.


The 2711P-B12C10D6 PanelView Plus 1250 comes pre-installed with the latest version of the FactoryTalk operating system. This software offers a number of convenient features, such as a built-in document viewer, and the ability to instantly provide feedback on monitoring services that are configured on this device. The input power requirements of the 2711P-B12C10D6 PanelView Plus 1250 can range between 85 and 264 Volts AC, depending on the power requirements of the operations that the display terminal will be used for.





Specifications:

The table below describes the parameters of the Panelview Plus 1250 2711P-B12C10D6 Operator Panel Parts

Part Number: 2711P-B12C10D6
Display Size: 12.1 inches
Display Color: Amber
Warranty: 365 days Warranty
Product Line: Panelview Plus 1250
Input Type: Touchscreen Keypad
Mounting Position: vertical
Communication: Ethernet and RS-232
Communication: ControlNet
Software: FactoryTalk


Related Allen Bradley Panelview Plus Terminals HMI Part No. :

PanelView Plus HMI Description Inventory status
2711P-B7C1D6 PanelView Plus Touch Membrane LCD Display Terminal Keypad Housing In Stock
2711P-B7C10D6 PanelView Plus HMI Touch Glass Membrane Keyboard LCD Display Screen Plastic Case Available Now
2711P-B10C1D6 Panel View Plus HMI Panel Glass LCD Screen Membrane Keypad HMI Case In Stock
2711P-B10C10D6 Panel View Plus Touchscreen LCD Display Membrane Switch Plastic Case In Stock
2711P-B12C1D6 PanelView Plus Touch Screen Membrane Keyboard Keypad LCD Display Housing In Stock
2711P-B12C10D6 PanelView Plus Touch Screen Membrane Keypad Switch LCD Display Screen HMI Case In Stock
2711P-B15C1D6 PanelView Plus Touch Screen Operator Keyboard LCD Display Panel Plastic Cover Body Available Now
2711P-B15C10D6 Allen Bradley PanelView Plus Touchscreen LCD Operator Panel Keypad Plastic Cover In Stock
PanelView Plus MMI Description Inventory status

AB Panelview Plus 1250 Manuals PDF Download:

  • 2711P-B12C10D6 Terminals User Manuals
  • panelview plus 1250 battery replacement Installation Instructions
  • PanelView Plus Operator Terminals 1250 dimensions datasheet manual
  • PanelView Plus 1250 Terminals and Display Modules
  • Allen Bradley PanelView Plus 1250 Terminal Operator Panel User Manual


  • FAQ:

    Question: What is the dimensions of Allen Bradley Panelview Plus 1250 2711P-B12C10D6 terminals?

    Answer: The 2711P-B12C10D6 terminals size is 12.1-inch.
    Allen Bradley Panelview Plus 1250 terminals dimensions


    Question: How to install Panelview plus 1250 HMI plastic case?

    Answer: Enclosures The terminals must be mounted in a panel or enclosure to protect the internal circuitry. The terminals meet IP54 and NEMA Type 12/13 and 4X (indoor) ratings only when mounted in a panel or enclosure with the equivalent rating. When the terminal is not mounted in a panel, it is not secure or safe for operation. You must comply with NEMA Type4X (indoor) requirements for environmental specifications.



    Question: How to rest the Allen Bradley PanelView 1250 2711P-B12C10D6 Terminal?

    Answer: All PanelView Plus 1250 terminals have both a Reset switch and a Default switch on the side of the logic module.

    How to rest the Allen Bradley PanelView 1250 2711P-B12C10D6 Terminal?

    • Reset

      Use the RESET switch to restart the terminal without having to disconnect and reapply power. Insert a thin probe into the hole marked RESET and press the switch. The terminal will perform a series of startup tests and run RSView ME or the loaded .MER application depending on how the terminal is configured.
    • Default

      Safe Mode is a diagnostics mode where the system is reduced to a known state that allows recovery from a configuration or application problem. Use the DEFAULT switch with the RESET switch to start the terminal in Safe Mode. This is a diagnostics mode where the system is reduced to a known state that allows recovery from a software problem. Safe Mode ignores all user changes to the system and avoids any problem that is due to interactions with end-user software or changes.
    • •Insert a thin probe into the hole marked DEFAULT and press the switch, then;
    • • Insert the probe into the hole marked RESET and press the switch. The system will restart immediately into the Safe Mode.

    • ATTENTION !

      Use a nonconducting object to press the RESET and DEFAULT switch. Do not use a conducting object such as a paper clip or you may damage the terminal. Do not use the tip of a pencil; graphite may damage the terminal.


    Question: What is the 2711P-B12C10D6 Panelview Plus 1250 price?

    Answer: Submit a fast quote, send VICPAS an email for best price.



    Common misspellings: 

    2711P-12C10D6
    2711P-B12C1D6
    2711PB-12C10D6
    2711P-B1ZC10D6
    2711P-B12C100D6
    2711PP-B12C10D6