Operator Keyboard for Horner Automation HE693OIU157
Operator Keyboard for Horner Automation HE693OIU157
Model
Horner Automation HE693OIU157

Item specifics

Touch screen panel type
Resistance touch screen
Product Line
VICPAS HMI Parts Horner Automation
Supply Parts
HE693OIU157 Operator Panel Keypad
Shipping
2-4 workdays
Warranty
365 Days

Review

Description

Horner Automation HE693OIU157 Membrane Switch Repair Replacement


Switch Membrane for Horner Automation HE693OIU157 repair replacement

Safety is a paramount concern in industrial settings, and Horner Automation HE693OIU157 Terminal Keypad HMIs play a crucial role in ensuring operator safety. They can provide visual and audible alerts, warnings, and alarms, notifying operators about critical conditions or emergencies. Operators can quickly respond to these alerts, taking necessary actions to prevent accidents, protect personnel, and preserve equipment integrity.


HE693OIU157 Membrane Keyboard HMIs are designed to be user-friendly and customizable. Operators can personalize the interface layout, preferences, and display options according to their specific needs. This flexibility allows operators to optimize the interface for their workflow, enhancing efficiency and usability.


In summary, HE693OIU157 Membrane Keypad HMIs are indispensable tools in the automation industry, providing operators with real-time data visualization, control functionalities, data analysis capabilities, and safety features. They empower operators to monitor and control industrial processes effectively, enabling efficient operations, informed decision-making, and a safe working environment.




Specifications:

The table below describes the parameters of the HE693OIU157 Membrane Keyboard Keypad Spare Part.

Number of Touches: Single
Product Line: VICPAS
Interface: USB / RS232 / COMBO
Warranty: 1-Year Warranty
Touch Activation Force: Stylus ≦ 50g
Contact Resistance: Typically less than 200 mΩ
Linearity: X ≦ 1.5%, Y ≦ 1.5%
Tail Options: FFC/ FPC tail
Part Number: HE693OIU157
Response time: ≦ 20ms


Related HMI Repair Replacement Part No. :

HMI Replacement Part Description Inventory status
Horner Automation HE693OIU157 Horner Automation HE693OIU157 HMI Membrane Switch Repair Available Now
N56016 N56016 Terminal Keypad Repair Replacement In Stock
Moistrex MX8000 Moistrex MX8000 Membrane Keyboard Replacement Repair Available Now
TERMINAL-K 6335234 TERMINAL-K 6335234 Membrane Keypad Replacement In Stock
Malux 4440.021-10001 Malux 4440.021-10001 Membrane Keyboard Keypad Repair In Stock
Riello Riello PCB Keypad Repair Replacement In Stock
Bromma SCS3 Bromma SCS3 Operator Panel Keypad Repair In Stock
PILZ PMI V316 PILZ PMI V316 Operator Keyboard Repair Available Now
GORMAN-RUPP PUMPS EPS 2000 GORMAN-RUPP PUMPS EPS 2000 HMI Keyboard Membrane Replacement Available Now
104SP-X101-2535-TS 104SP-X101-2535-TS Keypad Membrane In Stock
HT401-4X20/B/21572 HT4014X20B21572 KEBA MMI Switch Membrane Repair In Stock
HT401-4X20 KEBA HT401-4X20 HMI Terminal Keypad Replacement Available Now
HT401-232-4/0/53694 Folientastatur HT401-232-4/0/53694 Membrane Keyboard Repair In Stock
HT401-232-4/0 Keba 401-232-4/0 Membrane Keypad MMI Replacement Available Now
HT401-232/281 Folientastatur HT401-232/281 Membrane Switch HMI Repair In Stock
HMI Repair Part Description Inventory status

Horner Automation Manuals PDF Download:

  • HE693OIU150, HE693OIU152, HE693OIU175 User Manual
  • Installation Requirements for Conformance to Standards
  • User Manual, for HE693OIU057, HE693OIU157, HE693OIU177,...

  • FAQ:

    Question: Can HE693OIU157 Membrane Keypad Switches be made waterproof or resistant to liquids?

    Answer: Yes, HE693OIU157 Operator Panel Keypads can be designed to be waterproof or resistant to liquids. They can be constructed with sealed layers and IP-rated designs to prevent water or liquid ingress, making them suitable for industrial or outdoor environments.


    Question: Can HE693OIU157 Operator Keyboards be used with gloved hands?

    Answer: Yes, HE693OIU157 Keyboard Membranes can be designed to be glove-friendly. By using appropriate materials and adjusting the sensitivity of the keys, they can be operated effectively even with gloved hands.


    Question: Are HE693OIU157 Keypad Membranes compatible with different interface protocols?

    Answer: Yes, HE693OIU157 Switch Membranes can be designed to be compatible with various interface protocols such as USB, PS/2, RS-232, or I2C. This allows them to be easily connected to different devices and systems.


    Question: Can HE693OIU157 Terminal Keypads support multi-level key pressing or simultaneous key combinations?

    Answer: Yes, HE693OIU157 Membrane Keyboards can be designed to support multi-level key pressing or simultaneous key combinations. This can be achieved through the design of matrix layouts or using specific circuitry.


    Common misspellings: 

    HE693OIU57

    HE63OIU157

    HE693OI1U57

    HE693OIU15T

    HE6930IU157

    HE693OIIU157

    HE6993OIU157