Nidec Corp UNI2403 3847-1120-07 Control Housing Repair
Nidec Corp UNI2403 3847-1120-07 Control Housing Repair
Nidec Corp UNI2403 3847-1120-07 Control Housing Repair
Nidec Corp UNI2403 3847-1120-07 Control Housing Repair
Nidec Corp UNI2403 3847-1120-07 Control Housing Repair
Nidec Corp UNI2403 3847-1120-07 Control Housing Repair
Model
UNI2403 3847-1120-07

Item specifics

Brand
Nidec Corp
Warranty
365 Days
Supply
Nidec Corp UNI2403 3847-1120-07 Control HMI Case
Part Number
UNI2403 3847-1120-07
Shipping
2-4 workdays

Review

Description

Nidec Corp UNI2403 3847-1120-07 Control Housing Repair Replacement


Nidec Corp UNI2403 3847-1120-07 Control HMI Case Repair Replacement

VICPAS supplies Nidec Corp UNI2403 3847-1120-07 Control Plastic Case with 365 days warranty and supports Urgent Worldwide Shipping. These electronic drive products are intended to be used with appropriate motors, controllers, electrical protection components and other equipment to form complete end products or systems. Compliance with safety and EMC regulations depends upon installing and configuring drives correctly, including using the specified input filters. The Nidec Corp UNI2403 3847-1120-07 Control Plastic Shell drives must be installed only by professional assemblers who are familiar with requirements for safety and EMC.


The Nidec Corp UNI2403 3847-1120-07 Control Plastic Cover drive is intended as a component for professional incorporation into complete equipment or a system. If installed incorrectly, the drive may present a safety hazard. The drive uses high voltage and currents, carries a high level of stored electrical energy, and is used to control equipment that can cause injury.


Close attention is required to the electrical installation and the system design to avoid hazards, either in normal operation or in the event of equipment malfunction.




Specifications:

The table below describes the parameters of the Nidec Corp UNI2403 3847-1120-07 Control Enclosure HMI Parts.

Default Function: Frequency/Speed Reference
Input Voltage: 12/24 V dc ±20%
Input Resistance: 100kΩ
Voltage Range: 0V to +24V
Voltage Tolerance: ±10%
Brand: Nidec Corp
Contact Condition: Normally open
Noise Voltage: 1500 V p-p
Update Period: 8ms
Warranty: 365 Days


Related HMI Part No. :

HMI Replacement Part Description Inventory status
DTS640480-000 DU30 DTS640480-000 DU30 HMI Touch Screen Glass Replacement Available Now
DSC01361 DSC01361 Touch Screen Panel Replacement Repair In Stock
CALDARO AB I401-8121 CALDARO AB I401-8121 Touch Membrane Repair Replacement In Stock
BC42611854 BC42611854 Touch Glass Replacement Repair In Stock
B070N18AG04-02 E217342 B070N18AG04-02 E217342 Touch Digitizer Glass Repair Available Now
1042DF12 1042DF12 HMI Panel Glass Replacement Repair Available Now
A1016C-32 S130521-5080 A1016C-32 S130521-5080 Touch Screen Monitor Replacement In Stock
UNI2403 3847-878803 UNI2403 3847-878803 Side Cover Replacement In Stock
UNI2403 3847-1120-07 UNI2403 3847-1120-07 Control Housing Replacement Repair Available Now
HMI Repair Part Description Inventory status


Nidec Corp UNI2403 3847-1120-07 Control Manuals PDF Download:

  • Unidrive User Guide (Iss9)

  • FAQ:

    Question: How to choose a Mounting Location?

    Answer:
    How to choose a Mounting Location?
    Remove terminal covers, as follows:
    1. Working on either side of the terminal cover, push the inner edge of the cover firmly outward until it becomes unclipped.
    2. Swing the side of the cover outward and upward until the remaining clips become released.
    3. Remove the gland plate


    Question: How to remove the three terminal covers on the Size 5 power module?

    Answer:
    How to remove the three terminal covers on the Size 5 power module?
    Remove the three terminal covers on the power module, as follows:
    1. Remove the two posidrive screws.
    2. Remove the upper cover.
    3. Remove the two posidrive screws.
    4. Remove the lower cover until it is released from the middle cover.
    5. Remove the four screws that are now revealed.
    6. Remove the middle cover.
    All the power terminals and ribbon-cable connectors are now accessible.