FOG-VS090VXN01V0 GVS VS090VXN01V0 160705E-YZ Touch Screen Glass
- Model
- FOG-VS090VXN01V0 GVS VS090VXN01V0 160705E-YZ
Item specifics
- Warranty
- 365 Days
- Product Line
- VICPAS
- Supply
- Touch Screen Panel and Protective Film
- Shipping
- 2-3 workdays
- Part Number
- FOG-VS090VXN01V0 GVS VS090VXN01V0 160705E-YZ
- Touch Size
- 10.4 inches
Review
Description
FOG-VS090VXN01V0 GVS VS090VXN01V0 160705E-YZ HMI Touch Screen Front Overlay
VICPAS supply FOG-VS090VXN01V0 GVS VS090VXN01V0 160705E-YZ Front Overlay and Touch Screen with 365 Days warranty and support Urgent Worldwide Shipping.
Panel is a user-friendly, intuitive and ergonomic operator panel that combines slim, space-saving dimensions with a comprehensive range of advanced functions. FOG-VS090VXN01V0 GVS VS090VXN01V0 160705E-YZ Touch Screen Tablet Protective Film Panel family comprises user-friendly, intuitive and ergonomic operator panels that combine slim, space-saving dimensions with a comprehensive range of advanced functions. Adding to the already well-established feature-rich Panel our new Rugged and Black panels are designed to perform in challenging harsh environments. Whether it is heavy outdoor use, usage in areas with explosion risk, or ship bridge use in marine applications, they are ready to provide you with the information needed.
Designed to make process automation easy, FOG-VS090VXN01V0 GVS VS090VXN01V0 160705E-YZ Touchscreen Front Overlay HMI panels are equipped with advanced process and equipment control functionality, maneuvered by touching the LCD display. With market-leading performance and stunning graphical ability, Panel erodes the line between ordinary Operator Panels and PC- based HMIs. Panels are configured using Panel Builder tool which contains a wide range of advanced functions. The functions are tested and developed with customer needs and preferences in focus.
Specifications:
The table below describes the parameters of the FOG-VS090VXN01V0 GVS VS090VXN01V0 160705E-YZ Protective Film Touch Panel Panel.
Brand: | VICPAS |
Part Number: | FOG-VS090VXN01V0 GVS |
Product Number: | VS090VXN01V0 160705E-YZ |
Backlight: | LED/CFL |
Display Type: | TFT Color LCD |
Backlight Lifetime: | 50,000 hours |
Display Resolution: | 1024 × 768 pixels |
Operating Temperature: | -10 °C to +60 °C |
Storage Temperature: | -20 °C to +70 °C |
Warranty: | 365 Days |
Related HMI Panel Terminals Part No. :
HMI Repair | Description | Inventory status |
3HAC034169-001 | 3HAC034169-001 CABLE HARNESS CD27 BOX2 Repair | In Stock |
8136-500 CPU 5.1 033A1-0939A | HMI Panel Glass Repair Replacement | In Stock |
ACS100-PAN | Operator Panel Keypad HMI Replacement Repair | Available Now |
D674A906U01 | Proces/Hygienic Master 300 Cartridge Membrane Keypad Switch | Available Now |
EL3010 EL3010-IPA EL3020 EL3040 | Membrane Keyboard Keypad Replacement | In Stock |
FOG-VS090VXN01V0 GVS VS090VXN01V0 160705E-YZ | HMI Touch Digitizer Glass Replacement | In Stock |
GOP 2 B395976 / B395059 / B390868 | Graphic Operator Panel Terminal Keypad Replacement | Available Now |
GOP 2 G2010 A B394073 GOP2 B396858 G2010A10.4ST | Graphic Operator Panel Series Keyboard Membrane Repair | In Stock |
GOP GENERA G2010 A 10.4st | Graphic Operator Panel Keypad Membrane Replacement | Available Now |
GOP GENERA OY G2000 A 5.7HT | Touch Digitizer Switch Membrane Repair | In Stock |
Millmate Operator Unit 410 | Protective Film Touch Screen HMI Replacement | In Stock |
STT04 STT04EPS01J3 | Smart Transmitter Terminal Switch Membrane Replacement | In Stock |
SYNPOL D 3DDE 300 400 CMA 120 | SYNPOL D Membrane Keypad MMI Repair | Available Now |
SYNPOL D CMA130 | SYNPOL D Operator Keyboard Replacement | In Stock |
MMI Replacement | Description | Inventory status |
FAQ:
Question: Panel 800 Installation Process
Solution: The following is needed:
• ATorxTX7screwdriver
1. Unpack and check the delivery. If damage is found, notify the supplier.
2. Place the operator panel on a stable surface during installation. Dropping the operator panel or letting it fall may cause damage.
3. To cut a correct opening for the operator panel, use the cut out dimensions in the outline drawing.
4. Secure the operator panel in position by screwing the M4 Torx screw, allowing the built-in bracket to tighten against the panel:
5. Connect the cables in the specified order, according to the drawing and steps below.
• The operator panel must be brought to ambient temperature before it is started up. If condensation forms, ensure that the operator panel is dry before connecting it to the power outlet.
• Ensure that the operator panel and the controller system have the same electrical grounding (reference voltage level), otherwise errors in communication may occur.
• Ensure that the voltage and polarity of the power source is correct.
• Separate high voltage cables from signal and supply cables.
• Shielded communication cables are recommended.
– Connect cable A.
– Connect cable B, using an M5 screw and a grounding conductor (as short as possible), that is sized correctly according to local electrical codes.
– Connect cable C.
– Connect cable D. The recommended cross-section of the cable is 1.5 mm2..
6. Carefully remove the protective film over the operator panel display, take care to avoid static electricity that could damage the panel.
Common misspellings:
FOG-VS090VXN01V0 GVS V090VXN01V0 160705E-YZOG-VS090VXN01V0 GVS VS090VXN01V0 160705E-YZ
FOG-VS090VXN01V0 GVS VS090VXN010V 160705E-YZ
FOG-VS090VXN01V0 GVS VS090VXN01V0 1607o5E-YZ
FOG-VS090VXN011V0 GVS VS090VXN01V0 160705E-YZ