Siemens MP277 8 HMI Touch Screen Keypad
Size
8.4 inch
model
6AV6652-3LC01-1AA0

Review

Description

6AV6652-3LC01-1AA0 Siemens SIMATIC HMI Multi Panel MP277 8 Membrane Keyboard Keypad Plastic Case Repair Replacement

Order each part separately is available

6AV6652-3LC01-1AA0 Siemens SIMATIC HMI Multi Panel  MP277 8 Touch Screen, Keypad, Front Cover Housing, Mounting Clips, Power Supply Connector, LCD Display, Case Gasket Repair Replacement


VICPAS supply 6AV6652-3LC01-1AA0 Siemens MP 277 8 Membrane Keypad, Case Gasket, Power Supply Connector, Mounting Clips, LCD Screen, Protection Panel and Plastic Cover. All of them with VICPAS 365 days warranty and support Urgent Worldwide Shipping.


If the MP277-8 6AV6652-3LC01-1AA0 connection cable of the HMI device is disconnected from the connection box, the LEDs F2, F4, F6, F8 and F10 indicate the charge status of the bridging battery. The MP277-8 6AV6652-3LC01-1AA0 LED for function key F1 also lights up for max. 9.5 minutes. This duration applies to a 100% charge status. The duration reduces as the charge reduces. The LED F1 flashes for 30 seconds. The MP277-8 6AV6652-3LC01-1AA0 HMI device then switches off. Runtime is terminated.


The MP277-8 6AV6652-3LC01-1AA0 converter is required for the connection of controllers of other manufacturers. Connect the RS 422 to RS 232 converter to the RS 422 / RS 485 interface. The converter converts the input signals to RS-232 signals.


Do not write on the MP277-8 6AV6652-3LC01-1AA0 keyboard to label the function keys. Any printable and writable foil can be used as a labeling strip. The permitted thickness of the labeling strip is 0.13 mm. Paper labeling strips are inappropriate. You can use transparent foil, the keyboard membrane of the HMI device is printed on the reverse side. Use transparent foil so that the LEDs of the function keys can be seen.





Specifications:

The table below describes the parameters of the 6AV6652-3LC01-1AA0 Siemens MP277 HMI Parts.

Part Number : 6AV6652-3LC01-1AA0
Screen diagonal: 8.4 in
Design of display: TFT
Warranty: 365 days Warranty
Product Line: Siemens MP277 8
Function Keys: 26 function keys
MTBF backlighting (at 25 °C): 50 000 h
Brightness Control: Yes
Mounting position: vertical
Type of supply voltage DC


Related Simatic MP277 8 Part No. :

Siemens Multi Panel MP277 8 Description Inventory status
6AV6643-0DB01-1AX0 SIMATIC MP 277 8" KEY In Stock
6AV6643-0DB01-1AX1 SIMATIC MP 277 8" KEY Available Now
6AV6643-0DB01-1AX2 MP 277 8" KEY SMALL FRAME Available Now
6AV6643-0DB01-1AX5 MP 277 8" KEY In Stock
6AV6652-3LC01-1AA0 Siemens MP277-8 KEY Available Now
SIMATIC Multi Panel Description Inventory status

Siemens MP277 HMI Manuals PDF Download:

  • Siemens Simatic MP277 Panel manual
  • Siemens Simatic MP 277 8 KEY manual

  • FAQ:

    Question: How to setting the Siemens MP277-8 HMI 6AV6652-3LC01-1AA0's Date and Time?

    Answer:
    1. Select the appropriate time zone for the HMI device in the "Time Zone" selection box.
    How to setting the Siemens MP277-8 HMI 6AV6652-3LC01-1AA0's Date and Time?
    2. Touch the "Apply" button to confirm your entry.The time of day shown in the "Current Time" field is adjusted correspondingly to the selected time zone.
    3. Set the date in the selection box.
    4. Set the current time of day in the "Current Time" text box.
    5. If you want to switch from standard time to daylight saving time, select the "Daylight saving time currently in effect" check box.When you press the "Apply" button, the time is brought forward by one hour.
    6. If you want to switch from daylight saving time to standard time, deactivate the "Daylight saving time currently in effect" check box.When you press the "Apply" button, the time is brought back by one hour.
    7. Confirm your entries.The dialog box closes.The settings for the date and time of day have now been changed.


    Question: What is the dimension of Siemens MP277 8 6AV6652-3LC01-1AA0 membrane keypad?

    Answer:The Siemens MP277 8 membrane keypboard keypad is 8.4-inch. It is 153.7 millimeter long and 115.8 millimeters wide.


    Question: What is the MP277 KEY 6AV6652-3LC01-1AA0 Siemens MP277-8 HMI parts price?

    Answer: Submit a fast quote, send VICPAS an email for best price.


    Question: How to set the MP277-8 6AV6652-3LC01-1AA0 device name of the HMI device?

    Answer:1. Enter the device name for the HMI device in the "Device name" text box.
    2. Enter a description for the HMI device in the "Device description" text box.
    3. Confirm your entries.
    The dialog box and the screen keyboard are closed.