6SE3212-1CA40 6SE3212-7DA40 6SE3212-8BA40 HMI Enclosure
6SE3212-1CA40 6SE3212-7DA40 6SE3212-8BA40 HMI Enclosure
6SE3212-1CA40 6SE3212-7DA40 6SE3212-8BA40 HMI Enclosure
6SE3212-1CA40 6SE3212-7DA40 6SE3212-8BA40 HMI Enclosure
6SE3212-1CA40 6SE3212-7DA40 6SE3212-8BA40 HMI Enclosure
6SE3212-1CA40 6SE3212-7DA40 6SE3212-8BA40 HMI Enclosure
Model
6SE3212-1CA40 6SE3212-7DA40 6SE3212-8BA40

Item specifics

Supply
Siemens Micromaster Plastic Shell
Warranty
365 Days
Shipping
DHL/FedEx/UPS/TNT/EMS/Aramex /DPEX
Name
6SE3212-1CA40 6SE3212-7DA40 6SE3212-8BA40

Review

Description

Siemens Micromaster 6SE3212-1CA40 6SE3212-7DA40 6SE3212-8BA40 Plastic Cover Repair

Siemens Micromaster 6SE3212-1CA40 6SE3212-7DA40 6SE3212-8BA40 HMI Case Repair

The 6SE3212-1CA40 6SE3212-7DA40 6SE3212-8BA40 Plastic Shell MICROMASTER provides a PI control function for closed loop control. PI control is ideal for temperature or pressure control, or other applications where the controlled variable changes slowly or where transient errors are not critical. This control loop is not suitable for use in systems where fast response times are required. When closed loop PI control is enabled (P201 = 002), all setpoints are calibrated between zero and 100%, i.e., a setpoint of 50.0 = 50%. This allows general purpose control of any process variable that is actuated by motor speed and for which a suitable transducer is available.


Connect the outputs from the external feedback transducer to control terminals 3 and 4. This analogue input accepts a 0/2 - 10 V signal, has 10-bit resolution and permits a differential (floating) voltage. Ensure that the values of parameters P023 and P024 are set to 000 and that P006 is set to 000 or 002. 15 V dc/Max 50mA power for the feedback transducer can be supplied from terminals 8 and 9 on the control block.



Related Siemens Siemens Micromaster Part No. :

Simatic Micromaster Description Inventory status
6SE3210-7BA40 SIMATIC Siemens Micromaster Plastic Shell In Stock
6SE3210-7CA40 Siemens Micromaster Vector Plastic Enclosure Available Now
6SE3211-1BA40 Siemens Micromaster Drive Plastic Case Repair In Stock
6SE3211-1DA40 SIMATIC Siemens Micromaster Drive HMI Case Available Now
6SE3211-4DA40 SIMATIC Siemens Micromaster Inverter HMI Case In Stock
6SE3211-5BA40 Siemens Micromaster Inverter Plastic Cover In Stock
6SE3211-5CA40 Siemens Micromaster Vector Plastic Shell In Stock
6SE3212-0DA40 Siemens Micromaster VFD Plastic Housing Available Now
6SE3212-1BA40 Siemens Micromaster Inverter Plastic Cover Available Now
6SE3212-1CA40 SIMATIC Siemens Micromaster Plastic Case In Stock
6SE3212-7DA40 SIMATIC Micro Master Plastic Housing In Stock
6SE3212-8BA40 Siemens Micromaster Inverter HMI Enclosure In Stock
Siemens Micro Master Description Inventory status


Siemens Micromaster Vector Manuals PDF Download:

  • Simatic Siemens Micromaster 6SE92_Manual
  • Simatic Siemens Micromaster Vector Manual
  • Micromaster Drives 6SE92 Commissioning Manual

  • FAQ:

    Question: If the 6SE3212-1CA40 6SE3212-7DA40 6SE3212-8BA40 Enclosure Motor Does Not Start Up, what should we do?

    Answer:If the motor does not start up when the ON command has been given, check that the ON command is valid, check if a frequency setpoint has been entered in P005 and check that the motor specifications have been entered correctly under parameters P081 to P085.
    If the inverter is configured for operation via the front panel (P007 = 001) and the motor does not start when the RUN button is pressed, check that P121 = 001 (RUN button enabled).
    If the motor does not run after parameters have been changed accidentally, reset the inverter to the factory default parameter values by setting parameter P944 to 001 and then pressing P.


    Common misspellings: 

    6SE3212-1A40
    6E3212-1CA40
    6SE3212-D7A40
    6SE32l2-7DA40
    6SE3212-8BA4O
    66SE32122-8BA40